Low pressure is the single most common reason a boiler stops in Essex, and it is also the fault most people can sort themselves in five minutes. This guide shows you how to read the gauge, how to top up safely, and how to tell the difference between a boiler that needs a top-up once a year and one that is quietly leaking.
What the gauge should say
Most combi and system boilers run at between 1 and 1.5 bar when the heating is cold. Look for a round gauge with a green band, or a pressure figure on the display. Below about 0.5 bar most boilers lock out with a fault code: on a Baxi that is E119 (or E118 on the 600 and 800 series), on a Worcester Bosch CE 207 or H07, on a Vaillant or Glow-worm F.22 and on an Ideal F1. Our fault code guide covers 78 codes if yours is different.
How to top up the pressure
- Switch the boiler off and let it cool for a few minutes.
- Find the filling loop. It is usually a short braided silver hose under the boiler with a small valve at each end, or a lever or key built into the boiler itself. Some Worcester and Ideal models use a keyed filling link; the key lives in a slot on the base of the boiler.
- Open both valves slowly and watch the gauge. You will hear water running. Stop at 1.2 to 1.5 bar.
- Close both valves fully. If one is left open the pressure will creep up and the boiler will dump water through the pressure relief pipe outside.
- Turn the boiler back on and reset it once if it is showing a code.
If the filling loop is missing, disconnected or you cannot find it, do not improvise with a hose. Ring us and we will talk you through it, or come out and fit one.
How often is too often?
Topping up once or twice a year, usually after bleeding radiators, is normal. Topping up every few weeks is not, and it means water is leaving the system somewhere. The usual suspects, roughly in order:
- A weeping radiator valve or a pipe joint. Look for a damp patch or a white or green crust at the valves on each radiator.
- The pressure relief valve. A small copper pipe comes out through the wall next to the boiler. If it drips or there is a stain under it outside, the valve is passing and needs replacing.
- The expansion vessel. If the pressure shoots up when the heating is hot and drops back when cold, the vessel has lost its air charge. It can usually be recharged on a service, or replaced.
- The heat exchanger. On older boilers a hairline crack lets water out when hot. This is the expensive one, and often the point where a repair or replace conversation starts.
- Underfloor pipework. If nothing is visible and the pressure still drops, the leak may be in a pipe under a floor. A leak detection visit is the next step.
Hard water makes it worse
Water across Essex is hard to very hard, around 317 ppm on average, and limescale builds up on valves and seals, which is why so many of these small leaks start around the ten-year mark. A magnetic filter and a scale reducer on the cold feed slow it down, and both can be fitted on the same visit as a repair.
When to call us
Call if the pressure drops to zero and comes straight back down after a top-up, if there is water under the boiler, if you have topped up more than three times this winter, or if the boiler will not reset. Boiler repairs start from £90, the engineer diagnoses the fault and gives you the price to fix it before any parts go in, and the common parts for Baxi, Worcester Bosch, Vaillant and Ideal are carried on the van. If you have no heating or hot water and it is out of hours, our 24-hour line is answered by a person.
Questions
Is it safe to top up the boiler pressure myself?
Yes. Topping up with the filling loop is a normal user task and every manufacturer explains it in the manual. Go slowly, stop at 1.5 bar, close both valves afterwards and do not top up more than once a month without getting the system checked.
Why does my boiler pressure go up when the heating is on?
Water expands as it heats. A healthy expansion vessel absorbs that. If the pressure climbs by more than about half a bar and the relief pipe outside drips, the vessel has lost its charge and needs recharging or replacing.
What does it cost to find a leak on the heating system?
A repair visit starts from £90. Most leaks are found at a radiator valve or the boiler itself on the first visit and fixed there and then. Leaks under floors need a leak detection visit, which we quote separately before starting.
Can I run the boiler on low pressure for a few days?
If it is above 0.5 bar it will usually run, but low pressure makes the pump work harder and can let air into the system. Top it up, then find out why it dropped.